Products

K3B alcohol tester

  • Detailed Description

Breath alcohol content detector

11

 

I. Appearance Diagram and Button Description

0-1

1 (1)

 

II. Specifications

2 (1)

 

III. Instructions for Use

Before use, please check that the batteries are installed correctly. Unscrew the battery cover counterclockwise, insert the batteries into the battery compartment according to the positive and negative terminals, and tighten the battery cover clockwise.

I. Alcohol Concentration Detection: Press and hold the "Power On/Off/Alcohol Detection/Confirm" button for 2 seconds to turn on the machine. The screen will display the power-on screen (Figure 1).

Press the button again briefly. The voice prompt will say, "Device is preparing, please wait patiently," and "Please blow into the air." The screen will display "Please blow into the air" (Figure 2). After blowing into the air for 2-4 seconds:

A. If no alcohol is detected in the sample, the voice prompt will say, "You have not consumed alcohol, thank you for your cooperation," and the screen will display "No alcohol consumed" (Figure 3);

B. If alcohol is detected in the sample, the indicator light will flash red, and the voice prompt will say, "You have been drinking and driving, please cooperate with the inspection." The screen will display "Drinking alcohol + alcohol concentration (00 mg/100mL)" (Figure 4).

After powering on, press and hold the "Power On/Off/Alcohol Detection/Confirm" button for 3 seconds to turn off the machine. The screen will display the power-off screen (Figure 5).

3 (1)

Note: It is best to turn off the baton and flashlight when conducting alcohol concentration testing to avoid unnecessary visual interference to the person being tested.

II. Baton Operation: Briefly press the "Warning Light/Lighting/Down Button" to turn the baton on continuously. Short presses cycle through the options: continuously lit, flashing, and off.

III. Flashlight Operation: Press and hold the "Warning Light/Lighting/Down Button" to turn the flashlight on continuously. Press and hold again to turn it off.

IV. Whistle Operation: Briefly press the "Electronic Whistle/Up Button"; the machine will beep once. Press and hold the "Electronic Whistle/Up Button"; the machine will beep once.

V. Menu Settings: With the device powered on, briefly press the "Menu/Return Button" to enter the menu settings interface. Use the "Electronic Whistle/Up Button" / "Warning Light/Lighting/Down Button" to navigate up and down. Use the "Power On/Off/Alcohol Testing/Confirm" buttons to confirm. Briefly press the "Menu/Return Button" to return to the previous screen.

You can configure or view eight menu items: "Machine Calibration, Clock Setting, Record Query, System Settings, Voice Settings, Version Information, Device Number, and Alarm Settings".

4 (1)

 

VI. Window Breaker
Screen the window breaker cap counterclockwise to open. The window breaker can be used in emergencies.

VII. Magnet
The handle has a magnet at the end, allowing the device to be attached to metal.

VIII. Charging Operation
Use the included adapter and USB cable to connect to the device's USB port for charging. The display screen and red indicator light on the head will illuminate during charging. A full charge takes approximately 3 hours.

IX. Applications
The breathalyzer is suitable for traffic police to quickly detect drunk driving. It can also be used in government agencies, mining and transportation companies for inspections in hazardous work areas, and for drunk driving prevention in entertainment venues.

X. Product Function Description
The breathalyzer uses a rapid detection method, continuously extracting the breath of the person being tested to quantitatively or qualitatively determine whether the person has consumed alcohol. The instrument can analyze and determine the result within 3 seconds. The instrument has extremely high sensitivity, minimizing the possibility of false negatives.

 

IV. Precautions:

1. Prevent the machine from being dropped from a height or subjected to severe vibration;

2. This product must not be stored or used in an environment containing corrosive gases (such as chlorine);

3. This product must use the original 4.35V/3000mAh 18650 lithium battery supplied by the manufacturer, and the battery must not be placed in a high-temperature environment;

4. Please use the power adapter supplied by the manufacturer when charging. Using a power adapter not supplied by the manufacturer may damage the instrument.

Contact Us

Shenzhen Hengzhisheng Electronic Technology Co., Ltd.

Contact Person: Mr. Yang

Tel: 13266649641

Address: Room 801, Building A, No. 280, Dabutou Village, Songxuan Community, Guanhu Street, Longhua District, Shenzhen

Follow us